SILENT KNIGHT 5700 Informations techniques

Naviguer en ligne ou télécharger Informations techniques pour Systèmes de contrôle d'accès de sécurité SILENT KNIGHT 5700. SILENT KNIGHT 5700 System information Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 14
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
151295 8-1
Section 8
System Operation
Operation of the control panel is simple. Menus guide you step-by-step through operations.
This section of the manual is an overview of the operation menus. Please read this entire
section carefully before operating the panel.
Press to view Main Menu: Select the desired menu option. Enter your access code if
prompted.
Note: See Section 7.8 for information on how to modify user access code profiles.
Default Codes:
User Code (factory-programmed as 1111).
Installer Code (factory-programmed as 123456).
8.1 Annunciator Description
Figure 10-1 shows the annunciator that is part of the control panel board assembly.
Figure 8-1 Control Panel Annunciator
8.1.1 LCD Displays
The control panel LCD displays system messages, annunciates alarms, supervisories and
troubles; provides status information; and prompts for input. These messages can be up to 80
characters, displaying over four lines of 20 characters each. Annunciator keys beep when they
are pressed.
Vue de la page 0
1 2 3 4 5 6 ... 13 14

Résumé du contenu

Page 1 - System Operation

151295 8-1Section 8System OperationOperation of the control panel is simple. Menus guide you step-by-step through operations. This section of the manu

Page 2 - 8.2 Menu System

Model 5700 Installation and Operation Manual8-10 1512958.4 Operation Mode BehaviorThe control panel can be in one of seven conditions at any given mom

Page 3 - 8.3 Basic Operation

System Operation151295 8-11Trouble A system trouble condition occurs.The dialer seizes control of the phone line and calls the central station.The on-

Page 4 - 8.3.4 Conduct a Fire Drill

Model 5700 Installation and Operation Manual8-12 1512958.5 Releasing OperationsThis control panel supports two types of releasing, Double Interlock Zo

Page 5 - 8.3.6 Conduct a Walk Test

System Operation151295 8-138.5.1 Single Interlock Zone ReleasingA single interlock zone utilizes a minimum of two addressable detectors, and a designa

Page 6 - 8.3.9 Reset alarms

Model 5700 Installation and Operation Manual8-14 1512958.5.2 Double Interlock Zone ReleasingA Double Interlock Zone uses a minimum of two Addressable

Page 7 - 8.3.14 Reset dialer

Model 5700 Installation and Operation Manual8-2 1512958.1.2 BannerThe banner is the message that displays on the control panel when the system is in n

Page 8 - 8-8 151295

System Operation151295 8-38.2.1 Main Menu OverviewThe chart below is a brief overview of the Main Menu. These options are described in greater detail

Page 9 - 8.3.16 Working with a Printer

Model 5700 Installation and Operation Manual8-4 1512958.3.2 Disable / Enable a Point1. From the Main Menu, select for Point Functions. 2. Select f

Page 10 - 8.4 Operation Mode Behavior

System Operation151295 8-58.3.5 Conduct an Indicator TestThe indicator test checks the annunciator LEDs, PZT, and LCD display.1. From the Main Menu, p

Page 11

Model 5700 Installation and Operation Manual8-6 1512958.3.7 Conduct a Dialer Test1. From the Main Menu, press for System Tests.2. Select for Diale

Page 12 - 8.5 Releasing Operations

System Operation151295 8-75. A screen similar to those shown in Figure 8-3 will display.Figure 8-3 Checking Detector Sensitivity ComplianceIf a print

Page 13

Model 5700 Installation and Operation Manual8-8 1512958.3.15 Communicating with a Remote ComputerAn installer at the panel site can initiate communica

Page 14 - 8-14 151295

System Operation151295 8-98.3.16 Working with a PrinterIf you are using the Model 5824 Serial/Parallel Interface, several printing options are availab

Commentaires sur ces manuels

Pas de commentaire