SILENT KNIGHT 5084 Manuel d'installation Page 42

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 58
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 41
Operation Modes
151174 4-9
8. Enter the time you wish to enable the auxiliary door relay.
9. Press *. The display shows AUX DISABLE TIME
XX:XX.
X = a number from 0-9. Enter time based on a 24 hour clock (military time).
This feature sets the ending time of the auxiliary relay time window.
10. Enter the time you wish to disable the auxiliary door relay.
11. Press *.
4.2.4 Operating Mode 3
Activate Door Relay
Operating Mode 3 activates door relay for the time set in Door Time of the system options
(see 4.2.1 step 22 for step-by-step instructions on how to set Door Time).
To activate door relay use the following procedure:
1. Press * then 3. The display will showACCESS #
2. Enter the 6-digit access code. (Factory default is 123456.)
The display shows DOOR IS OPEN.
The door relay stays active for the “door time”.
4.2.5 Operating Mode 4
Activate Auxiliary Relay
Operating Mode 4 activates the auxiliary relay when Aux Relay is programmed as Enabled
(see also Section 4.2.1 step 28 for Aux relay programming).
To activate the auxiliary relay:
1. Press * then 4. The display will showACCESS #
2. Enter the 6-digit access code. (Factory default is 123456.)
The display shows DOOR IS OPEN.
The auxiliary door remains open for “door time”.